EcoFlow Smart 1800W Petrol Inverter Generator
SKU: EFGASGEN4L Learn More»Product Description
EcoFlow Smart 1800W Petrol Inverter Generator, 1 Year Warranty. Integrates with DELTA Pro/Max Link with your DELTA Pro or Max to charge up during extended blackouts.
Efficiency First Compared to traditional gas generators, the EcoFlow Smart Generator charges directly with DC, saving you fuel and charge time.
Charge & Power Features an AC output so you can power devices during emergencies while your power station charges up.
Smart, Really Smart Auto-start at your set charge level. Control & monitor via the app. Auto shutdown. That’s smart.
Built for any emergency.
Compared to a traditional gas generator, the EcoFlow Smart Generator offers better fuel efficiency and less energy loss when you charge DELTA Pro or DELTA Max. It achieves this by directly charging your portable power station through a simple and efficient DC charging process.
Charge and power devices at the same time.
In emergencies, sometimes things don’t go to plan. Not only does the EcoFlow Smart Generator give you last-standing emergency power, it also features an AC output to power other devices while recharging your unit with an extra battery.
Four easy ways to start.
Stay powered on at any time, using four easy ways to start the EcoFlow Smart Generator. If you’re close to the unit, you can turn it on via electric or manual start. In emergencies, when you can’t go outdoors, you can turn the smart generator on with the EcoFlow app. And for an added layer of power security and efficiency, the smart generator automatically turns on and off when your unit reaches a designated battery limit.
Control and monitor with the EcoFlow app.
The EcoFlow app gives you complete control over the EcoFlow Smart Generator at the touch of a button. You can control, monitor, and access your smart generator settings, such as choosing when it autostarts during an emergency.
Smart emergency power.
The EcoFlow Smart Generator simplifies emergency power, featuring an LCD screen, CO alert, fuel alert, and an auto shutdown – giving you everything you need to stay safe during a power outage or emergency.
Specifications
SKU EFGASGEN4L
Brand EcoFlow
GTIN 4897082664963
Warranty Period: 1 Year
Product Category Inverter Generators
Maximum Output (Watts) 1800
Fuel Tank Capacity 4 L
Cont. Working Time 3.5 hrs (full load)
Noise @ 7m 56~67dB (full load)
Product Dimensions (mm) LxWxH 597mm x 296mm x 475mm
Frequency 60Hz
DC Output 42-58.8V
Type Single cylinder, four-stroke, forced-air cooling, overhead value
Displacement 79.7cc
Rated Power 1800W (1900W peak)
Oil Capacity 0.38 L
Net Weight (kg) 28.5
Videos
How to use the EcoFlow Smart Generator
How to Maintain Your EcoFlow Smart Generator
Product Q&A
-
Can it be used indoor?
Like any gas generator, it must be placed outside 15 feet from doors and windows to prevent carbon monoxide poisoning. The Smart Generator automatically shuts off if it detects dangerous carbon-monoxide levels, but isn't a substitute for having CO detectors in other parts of your house.
-
What fuel does it use?
Unleaded gasoline.
-
What is the noise level?
The operational volume of the Smart Generator is 56 to 67dB at 7 meters, which is similar to office noise or a conversation.
-
How do I check the Spark Plug?
- Turn the maintenance cover knob to OPEN and take off the maintenance cover.
- Take off the spark plug cap.
- Use the spark plug socket and turn it counterclockwise to remove the
- spark plug.
- Check for any color fading and remove any carbon deposits. The porcelain center around the spark plug center electrode should be moderately light brown if it is in good condition.
- Check the model of the spark plug and that it has sufficient clearance.
-
How do I maintain the Muffler?
- Unscrew the bolts.
- Take off the muffler cap, muffler block, and spark plug arrestor.
- Clean the carbon deposits on the muffler block and the spark plug arrestor gently with a wire brush to avoid damaging or scratching the muffler block and spark plug collector.
- Check whether the muffler block or the spark plug arrestor is damaged, and replace it if damaged.
- Reinstall the parts in order.
-
How do I maintain the Fuel Filter Strainer?
- Take off the fuel cap and fuel filter screen.
- Clean the fuel filter screen with fuel.
- Wipe the filter screen and place it back into the fuel.
- Reinstall the fuel cap.
-
How do I maintain the Air Filter?
- Turn the maintenance cover knob to Open and take off the maintenance cover.
- Take off the screws and the air filter cover.
- Take off the foam filter element.
- Clean the foam filter element with soapy water or a nonflammable solvent and let it dry.
- Add oil to the foam filter element and squeeze out excess oil. The foam filter element should be wet but not drenched.
- Place the foam filter element into the air filter. Note: Make sure that the surface of the foam filter element is in close contact with the air filter, leaving no gap between them. Do not start the generator before reinstalling the air filter as excessive toxic gas may be produced and wear down the engine block.
- Install the air filter cover back to its original position and tighten the screws.
- Reinstall the maintenance cover and turn the knob to Closed.
-
How do I replace the Engine Oil?
- Place the Generator on a level surface, start it up, and keep it running for several minutes to warm it up. Turn off the Generator and turn the Engine Switch and the fuel cap breather knob to OFF.
- Turn the maintenance cover knob to Open and take off the maintenance cover.
- Unscrew the lid and dipstick.
- Place the oil basin under the Generator and tilt the unit so that the oil will drain quickly. If you replace the engine oil yourself, please dispose of the used oil properly. Store the used oil in a sealed container and take it to your nearest oil recycling center. Do not pour it into any trash can, onto the ground, or into the sewer. Note: Improper disposal of engine oil may harm the environment.
- Place the Generator in its original horizontal state.
- Refill the oil to the proper level. 7. Wipe the dipstick clean and remove any spilled oil. Prevent any foreign objects from entering the engine.
- Tighten the dipstick and lid.
- Reinstall the maintenance cover and turn the knob to Closed.
-
Can I adjust the Carburetor?
The carburetor is an essential part of the engine and should be adjusted by a dealer with professional knowledge, data, and equipment.
Changing the carburetor when working at high altitudes: The atmospheric pressure may reduce the amount of air that carburetors intake when running in high-altitude areas. This may cause its performance to decline and increase fuel consumption.
It may also affect the spark plug and make the engine hard to start. If at an altitude different from when the engine was certified, emissions may increase over an extended running time.
Modifying the carburetor may improve its high-altitude performance. If you continuously operate your generator above 3281 feet (1000 meters), contact your after-sales service dealer, who can modify the carburetor.
-
I think there might be an Internal Battery Issue?
Turn the maintenance cover knob to open, take off the maintenance cover and check whether the positive and the negative wires of the battery are connected correctly.
-
How do I fix an engine oil issue?
Check for oil leaks.
Check the oil level:
- Unscrew the lid, take out the dipstick and wipe it clean.
- Put the dipstick back without screwing it in, and check the oil level.
- Add oil if the oil level is low.
- Screw the dipstick and lid back in firmly.
-
How do I fix a fuel issue?
Take off the fuel cap and check the fuel level. Add more fuel if the fuel level is too low.
-
Can I Connect Devives to the AC Output Outets Before Starting the Generator?
Do not plug in any devices before starting the Smart Generator.
-
How to Connect the Smart Generator's Internal Battery?
The generator cannot be started by the Electric Start button unless the internal battery is connected. Turn the maintenance cover knob to OPEN, take off the maintenance cover and connect the positive and the negative wires of the battery.
-
How to Add Generator Engine Oil?
The Generator does not come with oil and needs to be filled before use. Do not tilt the Smart Generator when adding oil to prevent damaging the unit with excess oil.
-
How to Refuel the Smart Generator?
Do not overfill the fuel tank, as fuel may expand and spill out when the fuel tank warms up. Be sure to close the fuel cap tightly after refueling.
-
How many times will the smart generator charge the Delta Pro or the Delta Max in one full tank?
Smart Generator can recharge Delta Pro 1.2 times, or Delta Max 2.4 times.
-
Can I Charge Other Devices While Charging DELTA Pro/Max?
Yes, you can use the AC and DC outlets while recharging DELTA Max or DELTA Pro.
Customer Reviews
Warranty
For details relating to this product's warranty CLICK HERE
Delivery
For details relating to our delivery process CLICK HERE